1. INSTALL FRONT AIRBAG SENSOR
(a) Check that the engine switch is off.
(b) Check that the cable is disconnected from the negative (-) battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
(c) Before connecting the connector, check that the position of the white housing lock is as shown in the illustration.
*a | Incorrect | *b | Correct |
(d) Insert the front airbag sensor pin (stopper) into the body hole and install the front airbag sensor to the vehicle body with the bolt.
Torque:
9.0 N·m {92 kgf·cm, 80 in·lbf}
NOTICE:
(e) Connect the connector to the front airbag sensor.
*a | White Housing Lock | *b | Connection is completed |
NOTICE:
When connecting any airbag connector, take care not to damage the airbag wire harness.
HINT:
(f) Check that there is no looseness in the installed parts of the front airbag sensor.
2. INSTALL HEADLIGHT ASSEMBLY
Click here
3. INSTALL FRONT FENDER REINFORCEMENT SUB-ASSEMBLY TOP
Click here
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
Click here
5. INSTALL FRONT BUMPER ASSEMBLY
Click here
6. INSPECT AND ADJUST HEADLIGHT AIMING
Click here
7. PERFORM DIAGNOSTIC SYSTEM CHECK
Click here
8. INSPECT SRS WARNING LIGHT
Click here
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Air Conditioning System: Customize Parameters
CUSTOMIZE PARAMETERS CUSTOMIZE AIR CONDITIONING SYSTEM (a) Customizing with the Techstream. NOTICE:
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a ...
Lexus RX (RX 350L, RX450h) 2016-2024 Repair Manual > Refrigerant (for Hfo-1234yf(r1234yf)): On-vehicle Inspection
ON-VEHICLE INSPECTION PROCEDURE 1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET HINT: The following examples show the readings of a manifold gauge set and the corresponding air conditioning system problems. (a) Read the manifold gauge pressure when the following conditions are met:
Doors ...