INITIALIZATION
DESCRIPTION
(a) Zero point of the occupant classification sensors may deviate in the following situations. To ensure sensor accuracy, be sure to perform Zero Point Calibration.
HINT:
As the zero point is not automatically stored in a new occupant detection ECU, it is necessary to perform zero point calibration after replacing the occupant detection ECU.
HINT:
As the weight of accessories will be added to the weight of the occupant, the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
If any load or pressure is applied to the occupant classification sensors, the system will not be able to perform classification accurately.
HINT:
If the seat frame or vehicle floor has become deformed and additional pressure is applied to the occupant classification sensor, the system will not be able to perform classification accurately.
NOTICE:
Make sure that the front passenger seat is not occupied before performing the operation.
ZERO POINT CALIBRATION
(a) Zero point calibration procedure
(1) Check that all of the following conditions are met:
(2) Adjust the seat position according to the table below.
| Adjustment Item | Position |
|---|---|
| Slide Direction | Rearmost position |
| Headrest Height | Lowest position |
| Front Tilt Height | Lowest position |
| Seat Lifter Height | Lowest position |
| Recline Angle | Upright position |
| Leg Support* | Rearmost position |
(3) Turn the engine switch off.
(4) Connect the Techstream to the DLC3.
(5) Turn the engine switch on (IG).
(6) Turn the Techstream on.
(7) Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration.
Body Electrical > Occupant Detection > Utility| Tester Display |
|---|
| Zero Point Calibration |
(8) Perform zero point calibration by following the prompts on the Techstream screen.
OK:
"Zero Point Calibration is complete." is displayed.
HINT:
How To Proceed With Troubleshooting
Problem Symptoms TableLexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Engine Coolant Temperature Sensor: Removal
REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during engine coolant temperature sensor removal/installation are shown below. Necessary Procedures After Parts ...
Lexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Audio And Visual System (for 12.3 Inch Display): USB Device Malfunction (B1585)
DESCRIPTION This DTC is stored when a malfunction occurs in a connected device. DTC No. Detection Item DTC Detection Condition Trouble Area B1585 USB Device Malfunction When any of the following conditions is met:
A non mass-storage class or incompatible protocol USB device is co ...