INITIALIZATION
DESCRIPTION
(a) Zero point of the occupant classification sensors may deviate in the following situations. To ensure sensor accuracy, be sure to perform Zero Point Calibration.
HINT:
As the zero point is not automatically stored in a new occupant detection ECU, it is necessary to perform zero point calibration after replacing the occupant detection ECU.
HINT:
As the weight of accessories will be added to the weight of the occupant, the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
As the seat frame will warp slightly when the bolts that are used to install the front passenger seat are tightened, the load applied to the occupant classification sensor will change and the system will not be able to perform classification accurately.
HINT:
If any load or pressure is applied to the occupant classification sensors, the system will not be able to perform classification accurately.
HINT:
If the seat frame or vehicle floor has become deformed and additional pressure is applied to the occupant classification sensor, the system will not be able to perform classification accurately.
NOTICE:
Make sure that the front passenger seat is not occupied before performing the operation.
ZERO POINT CALIBRATION
(a) Zero point calibration procedure
(1) Check that all of the following conditions are met:
(2) Adjust the seat position according to the table below.
| Adjustment Item | Position |
|---|---|
| Slide Direction | Rearmost position |
| Headrest Height | Lowest position |
| Front Tilt Height | Lowest position |
| Seat Lifter Height | Lowest position |
| Recline Angle | Upright position |
| Leg Support* | Rearmost position |
(3) Turn the engine switch off.
(4) Connect the Techstream to the DLC3.
(5) Turn the engine switch on (IG).
(6) Turn the Techstream on.
(7) Enter the following menus: Body Electrical / Occupant Detection / Utility / Zero Point Calibration.
Body Electrical > Occupant Detection > Utility| Tester Display |
|---|
| Zero Point Calibration |
(8) Perform zero point calibration by following the prompts on the Techstream screen.
OK:
"Zero Point Calibration is complete." is displayed.
HINT:
How To Proceed With Troubleshooting
Problem Symptoms TableLexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Vehicle Stability Control System: ABS Operates Before Necessary When Braking
DESCRIPTION Troubleshooting for when ABS operates too soon due to a noisy signal from the speed sensor, a difference in output, etc. CAUTION / NOTICE / HINT NOTICE:
After replacing or removing and installing a speed sensor, perform Dealer Mode (Signal Check) inspection to confirm that the speed s ...
Lexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Airbag System: Short in P/T Squib (LH) Circuit (B1905-B1908)
DESCRIPTION The front pretensioner squib LH circuit consists of the airbag sensor assembly and front seat outer belt assembly LH. The airbag sensor assembly uses this circuit to deploy the pretensioner when deployment conditions are met. These DTCs are stored when a malfunction is detected in the fr ...