INSPECTION
PROCEDURE
1. INSPECT VACUUM PUMP VANE (for TMC Made)
| (a) Check that the vacuum pump vane or vacuum pump vane caps are not damaged or excessively worn out. HINT: If the vacuum pump vane or vacuum pump vane caps are damaged or excessively worn out, replace the damaged parts with new ones. |
|
| (b) Using a micrometer, measure length (A) of the vacuum pump vane with the vacuum pump vane caps removed. Minimum Length (A): 23.8 mm (0.937 in.) NOTICE: Measure the length 10 mm (0.394 in.) in from each end of the vacuum pump vane. HINT: If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones. |
|
| (c) Using a vernier caliper, measure length (B) of the vacuum pump vane with the vacuum pump vane caps installed. Minimum Length (B): 80.5 mm (3.17 in.) NOTICE: Measure the length 5 mm (0.197 in.) in from each end of the vacuum pump vane caps. HINT: If the length is not as specified, replace the vacuum pump vane and vacuum pump vane caps with new ones. |
|
2. INSPECT VACUUM PUMP HOUSING (for TMC Made)
| (a) Check that the areas shown in the illustration are not damaged or excessively worn out. HINT: If the areas shown in the illustration are damaged or excessively worn out, replace the vacuum pump assembly. |
|
Disassembly
ReassemblyLexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Dynamic Radar Cruise Control System: Brake Switch "A" Circuit Open (P057113)
DESCRIPTION When the brakes are applied by the dynamic radar cruise control system, the skid control ECU (brake actuator assembly) operates the stop light switch assembly (stop light control relay) to illuminate the stop lights. If the ECM receives a signal from the skid control ECU (brake actuator ...
Lexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Glove Box Light: Inspection
INSPECTION PROCEDURE 1. INSPECT GLOVE BOX LIGHT ASSEMBLY (a) Inspect the glove box light. (1) Apply battery voltage to each terminal of glove box light assembly connector and check the operation of the glove box light. Result: Connection Specified Condition Battery positive (+) → 2 Ba ...