1. INSPECT SHIFT SOLENOID VALVE S1
| (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the shift solenoid valve S1. |
|
(b) Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve S1 connector and a negative (-) lead to the shift solenoid valve S1 body, and check that the shift solenoid valve S1 moves and makes an operating sound.
NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK:
The shift solenoid valve S1 moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve S1.
2. INSPECT SHIFT SOLENOID VALVE S2
HINT:
Refer to Inspect Shift Solenoid Valve S1.
3. INSPECT SHIFT SOLENOID VALVE SLU
| (a) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the shift solenoid valve SLU. |
|
(b) Connect a positive (+) lead from the battery with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the shift solenoid valve SLU connector, and check that the shift solenoid valve SLU moves and makes an operating sound.
NOTICE:
When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK:
The shift solenoid valve SLU moves and makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SLU.
4. INSPECT SHIFT SOLENOID VALVE SL1
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
5. INSPECT SHIFT SOLENOID VALVE SL2
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
6. INSPECT SHIFT SOLENOID VALVE SL3
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
7. INSPECT SHIFT SOLENOID VALVE SL4
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
8. INSPECT SHIFT SOLENOID VALVE SL5
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
9. INSPECT SHIFT SOLENOID VALVE SLT
HINT:
Refer to Inspect Shift Solenoid Valve SLU.
Disassembly
RemovalLexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Lighting System (w/ Automatic Headlight Beam Level Control System): Lost Communication With Headlamp Control Module "B" (U0242)
DESCRIPTION for Multiple Beam Headlight:
The No. 1 headlight ECU sub-assembly LH communicates with the No. 1 headlight ECU sub-assembly RH via CAN communication. If communication between the No. 1 headlight ECU sub-assembly LH and No. 1 headlight ECU sub-assembly RH stops, the No. 1 headlight ECU ...
Lexus RX (RX 350L, RX450h) 2016-2026 Repair Manual > Air Conditioning System: Air Outlet Damper Control Servo Motor Circuit(Driver Side Front A/C Rear Air Flow) (B1486/86)
DESCRIPTION The Rear No. 1 cooling unit damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the Rear No. 1 cooling unit d ...