Lexus RX (RX 350L, RX450h) 2016-2025 Repair Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT SEMICONDUCTOR POWER INTEGRATION ECU

(a) IG2 RELAY:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

B-1 - 1F-4

Battery voltage not applied between terminals 1E-1 and 1D-14

10 kΩ or higher

B-1 - 1G-3

B-1 - 1G-4

B-1 - 1F-4

Battery positive (+) → 1E-1

Battery negative (-) → 1D-14

Below 1 Ω

B-1 - 1G-3

B-1 - 1G-4

If the result is not as specified, replace the semiconductor power integration ECU.

*a

Component without harness connected

(Semiconductor Power Integration ECU)

(b) EFI-MAIN RELAY:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

B-1 - 1G-1

Battery voltage not applied between terminals 1G-6 and 1D-14

10 kΩ or higher

B-1 - 1G-2

B-1 - 1G-7

B-1 - 1G-8

1F-2 - 1G-1

B-1 - 1G-1

Battery positive (+) → 1G-6

Battery negative (-) → 1D-14

Below 1 Ω

B-1 - 1G-2

B-1 - 1G-7

B-1 - 1G-8

1F-2 - 1G-1

If the result is not as specified, replace the semiconductor power integration ECU.

*a

Component without harness connected

(Semiconductor Power Integration ECU)

(c) A/F RELAY:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

B-1 - 1F-1

Battery voltage not applied between terminals 1G-1 and 1D-14

10 kΩ or higher

B-1 - 1F-1

Battery positive (+) → 1G-1

Battery negative (-) → 1D-14

Below 1 Ω

If the result is not as specified, replace the semiconductor power integration ECU.

*a

Component without harness connected

(Semiconductor Power Integration ECU)

(d) H-LP RH-LO RELAY:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

B-1 - 1E-2

Battery voltage not applied between terminals B-1 and 1D-8

10 kΩ or higher

*a

Component without harness connected

(Semiconductor Power Integration ECU)

(2) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Condition

Specified Condition

1E-2 - Battery negative (-)

Battery positive (+) → B-1

Battery negative (-) → 1D-8

11 to 14 V

If the result is not as specified, replace the semiconductor power integration ECU.

(e) H-LP LH-LO RELAY:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

B-1 - 1E-3

Battery voltage not applied between terminals B-1 and 1D-8

10 kΩ or higher

*a

Component without harness connected

(Semiconductor Power Integration ECU)

(2) Measure the voltage according to the value(s) in the table below.

Standard Voltage:

Tester Connection

Condition

Specified Condition

1E-3 - Battery negative (-)

Battery positive (+) → B-1

Battery negative (-) → 1D-8

11 to 14 V

If the result is not as specified, replace the semiconductor power integration ECU.

(f) Semiconductor power integration ECU ground:

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1D-14 - 1G-5

Always

Below 1 Ω

If the result is not as specified, replace the semiconductor power integration ECU.

*a

Component without harness connected

(Semiconductor Power Integration ECU)

    Removal
    REMOVAL CAUTION / NOTICE / HINT The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during int ...

    Installation
    INSTALLATION PROCEDURE 1. INSTALL SEMICONDUCTOR POWER INTEGRATION ECU (a) Connect the 5 connectors. (b) Engage the 2 claws to install the semiconductor power integration ECU as shown in the illustrati ...

    Other materials:

    Lexus RX (RX 350L, RX450h) 2016-2025 Repair Manual > Compressor: Inspection
    INSPECTION PROCEDURE 1. INSPECT COOLER COMPRESSOR ASSEMBLY (A/C LOCK SENSOR) (a) Measure the resistance according to the value(s) in the table below. Standard Resistance: Tester Connection Condition Specified Condition 1 (SSR+) - 2 (SSR-) 20°C (68°F) 160 to 320 Ω If the resi ...

    Lexus RX (RX 350L, RX450h) 2016-2025 Owners Manual > Steps to take in an emergency: If the 12-volt battery is discharged
    The following procedures may be used to start the hybrid system if the vehicle's 12-volt battery is discharged. You can also call your Lexus dealer or a qualified repair shop. If you have a set of jumper (or booster) cables and a second vehicle with a 12-volt battery, you can jump start yo ...

    Lexus RX (RX 350L, RX450h) 2016-{YEAR} Owners Manual

    Lexus RX (RX 350L, RX450h) 2016-{YEAR} Repair Manual

    © 2025 Copyright www.lexusrx.net
    0.0161